9-7-00.result_save 3.1 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293
  1. 2000 09 13 12:53:42 sommer NMMTL_2DLF
  2. Node = MRL_TFI_bem:9-7-00
  3. Number of Signal Lines = 3
  4. Number of Ground Lines, including top ground plane = 1
  5. Coupling Length = 0.04000 meters
  6. Rise Time = 400.0000 picoseconds
  7. Contour (conductor) segments [cseg] = 200
  8. Ground Plane/Dielectric segments [dseg] = 400
  9. Note: minimum frequency for surface current assumptions is 23841 MHz.
  10. Mutual and Self Electrostatic Induction:
  11. B(Active Signal , Passive Signal) Farads/Meter
  12. B( signal1 , signal1 )= 1.1508786e-10
  13. B( signal1 , signal2 )= -4.1967520e-13
  14. B( signal1 , signal3 )= -2.2046738e-16
  15. B( signal2 , signal1 )= -4.1965541e-13
  16. B( signal2 , signal2 )= 1.1508984e-10
  17. B( signal2 , signal3 )= -4.1967683e-13
  18. B( signal3 , signal1 )= -2.1666831e-16
  19. B( signal3 , signal2 )= -4.1965783e-13
  20. B( signal3 , signal3 )= 1.1508743e-10
  21. Mutual and Self Inductance:
  22. L(Active Signal , Passive Signal) Henrys/Meter
  23. L( signal1 , signal1 )= 3.0894662e-07
  24. L( signal1 , signal2 )= 1.1265915e-09
  25. L( signal1 , signal3 )= 4.7000351e-12
  26. L( signal2 , signal1 )= 1.1265384e-09
  27. L( signal2 , signal2 )= 3.0894546e-07
  28. L( signal2 , signal3 )= 1.1265960e-09
  29. L( signal3 , signal1 )= 4.6894467e-12
  30. L( signal3 , signal2 )= 1.1265415e-09
  31. L( signal3 , signal3 )= 3.0894708e-07
  32. Asymmetry Ratios:
  33. Asymmetry ratio for inductance matrix:
  34. 0.225282% (max), 0.078277% (average)
  35. **********
  36. Asymmetry ratio for electrostatic induction matrix:
  37. 1.723186% (max), 0.577476% (average).
  38. (Note values greater than 1% are a probable indication of too few elements.
  39. Try adjusting CSEG and DSEG attributes.)
  40. **********
  41. Characteristic Impedance (Ohms):
  42. For Signal Line signal1= 51.8116
  43. For Signal Line signal2= 51.8111
  44. For Signal Line signal3= 51.8117
  45. Effective Dielectric Constant:
  46. For Signal Line signal1= 3.2
  47. For Signal Line signal2= 3.2
  48. For Signal Line signal3= 3.19999
  49. Propagation Velocity (meters/second):
  50. For Signal Line signal1= 1.6758915e+08
  51. For Signal Line signal2= 1.6758915e+08
  52. For Signal Line signal3= 1.6758934e+08
  53. Propagation Delay (seconds/meter):
  54. For Signal Line signal1= 5.9669733e-09
  55. For Signal Line signal2= 5.9669733e-09
  56. For Signal Line signal3= 5.9669665e-09
  57. Rdc:
  58. Rdc(Active Signal , Passive Signal) Ohms/Meter
  59. Rdc( signal1 , signal1 )= 2.4767671e+02
  60. Rdc( signal1 , signal2 )= 0.0000000e+00
  61. Rdc( signal1 , signal3 )= 0.0000000e+00
  62. Rdc( signal2 , signal1 )= 0.0000000e+00
  63. Rdc( signal2 , signal2 )= 2.4767580e+02
  64. Rdc( signal2 , signal3 )= 0.0000000e+00
  65. Rdc( signal3 , signal1 )= 0.0000000e+00
  66. Rdc( signal3 , signal2 )= 0.0000000e+00
  67. Rdc( signal3 , signal3 )= 2.4767616e+02
  68. Far-End (Forward) Cross Talk:
  69. FXT(Active Signal, Passive Signal)
  70. FXT( signal1 , signal2 )= -9.51018e-09 = -160.43623 dB
  71. FXT( signal1 , signal3 )= -3.96418e-06 = -108.03694 dB
  72. FXT( signal2 , signal3 )= -3.47087e-09 = -169.19124 dB
  73. Near-End (Backward) Cross Talk:
  74. BXT(Active Signal, Passive Signal)
  75. BXT( signal1 , signal2 )= 1.82319e-03 = -54.78337 dB
  76. BXT( signal1 , signal3 )= 4.26536e-06 = -107.40088 dB
  77. BXT( signal2 , signal3 )= 1.82320e-03 = -54.78333 dB
  78. NOTE: Cross talk results assume there are no reflections.