- 2000 09 13 12:53:42 sommer NMMTL_2DLF
- Node = MRL_TFI_bem:9-7-00
- Number of Signal Lines = 3
- Number of Ground Lines, including top ground plane = 1
- Coupling Length = 0.04000 meters
- Rise Time = 400.0000 picoseconds
- Contour (conductor) segments [cseg] = 200
- Ground Plane/Dielectric segments [dseg] = 400
- Note: minimum frequency for surface current assumptions is 23841 MHz.
- Mutual and Self Electrostatic Induction:
- B(Active Signal , Passive Signal) Farads/Meter
- B( signal1 , signal1 )= 1.1508786e-10
- B( signal1 , signal2 )= -4.1967520e-13
- B( signal1 , signal3 )= -2.2046738e-16
- B( signal2 , signal1 )= -4.1965541e-13
- B( signal2 , signal2 )= 1.1508984e-10
- B( signal2 , signal3 )= -4.1967683e-13
- B( signal3 , signal1 )= -2.1666831e-16
- B( signal3 , signal2 )= -4.1965783e-13
- B( signal3 , signal3 )= 1.1508743e-10
- Mutual and Self Inductance:
- L(Active Signal , Passive Signal) Henrys/Meter
- L( signal1 , signal1 )= 3.0894662e-07
- L( signal1 , signal2 )= 1.1265915e-09
- L( signal1 , signal3 )= 4.7000351e-12
- L( signal2 , signal1 )= 1.1265384e-09
- L( signal2 , signal2 )= 3.0894546e-07
- L( signal2 , signal3 )= 1.1265960e-09
- L( signal3 , signal1 )= 4.6894467e-12
- L( signal3 , signal2 )= 1.1265415e-09
- L( signal3 , signal3 )= 3.0894708e-07
- Asymmetry Ratios:
- Asymmetry ratio for inductance matrix:
- 0.225282% (max), 0.078277% (average)
- **********
- Asymmetry ratio for electrostatic induction matrix:
- 1.723186% (max), 0.577476% (average).
- (Note values greater than 1% are a probable indication of too few elements.
- Try adjusting CSEG and DSEG attributes.)
- **********
- Characteristic Impedance (Ohms):
- For Signal Line signal1= 51.8116
- For Signal Line signal2= 51.8111
- For Signal Line signal3= 51.8117
- Effective Dielectric Constant:
- For Signal Line signal1= 3.2
- For Signal Line signal2= 3.2
- For Signal Line signal3= 3.19999
- Propagation Velocity (meters/second):
- For Signal Line signal1= 1.6758915e+08
- For Signal Line signal2= 1.6758915e+08
- For Signal Line signal3= 1.6758934e+08
- Propagation Delay (seconds/meter):
- For Signal Line signal1= 5.9669733e-09
- For Signal Line signal2= 5.9669733e-09
- For Signal Line signal3= 5.9669665e-09
- Rdc:
- Rdc(Active Signal , Passive Signal) Ohms/Meter
- Rdc( signal1 , signal1 )= 2.4767671e+02
- Rdc( signal1 , signal2 )= 0.0000000e+00
- Rdc( signal1 , signal3 )= 0.0000000e+00
- Rdc( signal2 , signal1 )= 0.0000000e+00
- Rdc( signal2 , signal2 )= 2.4767580e+02
- Rdc( signal2 , signal3 )= 0.0000000e+00
- Rdc( signal3 , signal1 )= 0.0000000e+00
- Rdc( signal3 , signal2 )= 0.0000000e+00
- Rdc( signal3 , signal3 )= 2.4767616e+02
- Far-End (Forward) Cross Talk:
- FXT(Active Signal, Passive Signal)
- FXT( signal1 , signal2 )= -9.51018e-09 = -160.43623 dB
- FXT( signal1 , signal3 )= -3.96418e-06 = -108.03694 dB
- FXT( signal2 , signal3 )= -3.47087e-09 = -169.19124 dB
- Near-End (Backward) Cross Talk:
- BXT(Active Signal, Passive Signal)
- BXT( signal1 , signal2 )= 1.82319e-03 = -54.78337 dB
- BXT( signal1 , signal3 )= 4.26536e-06 = -107.40088 dB
- BXT( signal2 , signal3 )= 1.82320e-03 = -54.78333 dB
- NOTE: Cross talk results assume there are no reflections.
|