123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191 |
- #
- # PMBus chip drivers configuration
- #
- menuconfig PMBUS
- tristate "PMBus support"
- depends on I2C
- default n
- help
- Say yes here if you want to enable PMBus support.
- This driver can also be built as a module. If so, the module will
- be called pmbus_core.
- if PMBUS
- config SENSORS_PMBUS
- tristate "Generic PMBus devices"
- default y
- help
- If you say yes here you get hardware monitoring support for generic
- PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
- MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, TPS40400, TPS544B20,
- TPS544B25, TPS544C20, TPS544C25, and UDT020.
- This driver can also be built as a module. If so, the module will
- be called pmbus.
- config SENSORS_ADM1275
- tristate "Analog Devices ADM1275 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Analog
- Devices ADM1075, ADM1275, ADM1276, ADM1278, ADM1293, and ADM1294
- Hot-Swap Controller and Digital Power Monitors.
- This driver can also be built as a module. If so, the module will
- be called adm1275.
- config SENSORS_IBM_CFFPS
- tristate "IBM Common Form Factor Power Supply"
- help
- If you say yes here you get hardware monitoring support for the IBM
- Common Form Factor power supply.
- This driver can also be built as a module. If so, the module will
- be called ibm-cffps.
- config SENSORS_IR35221
- tristate "Infineon IR35221"
- default n
- help
- If you say yes here you get hardware monitoring support for the
- Infineon IR35221 controller.
- This driver can also be built as a module. If so, the module will
- be called ir35521.
- config SENSORS_LM25066
- tristate "National Semiconductor LM25066 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for National
- Semiconductor LM25056, LM25066, LM5064, and LM5066.
- This driver can also be built as a module. If so, the module will
- be called lm25066.
- config SENSORS_LTC2978
- tristate "Linear Technologies LTC2978 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Linear
- Technology LTC2974, LTC2975, LTC2977, LTC2978, LTC2980, LTC3880,
- LTC3883, LTC3886, LTC3887, LTCM2987, LTM4675, and LTM4676.
- This driver can also be built as a module. If so, the module will
- be called ltc2978.
- config SENSORS_LTC2978_REGULATOR
- bool "Regulator support for LTC2978 and compatibles"
- depends on SENSORS_LTC2978 && REGULATOR
- help
- If you say yes here you get regulator support for Linear
- Technology LTC2974, LTC2977, LTC2978, LTC3880, LTC3883, and LTM4676.
- config SENSORS_LTC3815
- tristate "Linear Technologies LTC3815"
- default n
- help
- If you say yes here you get hardware monitoring support for Linear
- Technology LTC3815.
- This driver can also be built as a module. If so, the module will
- be called ltc3815.
- config SENSORS_MAX16064
- tristate "Maxim MAX16064"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX16064.
- This driver can also be built as a module. If so, the module will
- be called max16064.
- config SENSORS_MAX20751
- tristate "Maxim MAX20751"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX20751.
- This driver can also be built as a module. If so, the module will
- be called max20751.
- config SENSORS_MAX34440
- tristate "Maxim MAX34440 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX34440, MAX34441, MAX34446, MAX34460, and MAX34461.
- This driver can also be built as a module. If so, the module will
- be called max34440.
- config SENSORS_MAX8688
- tristate "Maxim MAX8688"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX8688.
- This driver can also be built as a module. If so, the module will
- be called max8688.
- config SENSORS_TPS40422
- tristate "TI TPS40422"
- default n
- help
- If you say yes here you get hardware monitoring support for TI
- TPS40422.
- This driver can also be built as a module. If so, the module will
- be called tps40422.
- config SENSORS_TPS53679
- tristate "TI TPS53679"
- help
- If you say yes here you get hardware monitoring support for TI
- TPS53679.
- This driver can also be built as a module. If so, the module will
- be called tps53679.
- config SENSORS_UCD9000
- tristate "TI UCD90120, UCD90124, UCD90160, UCD9090, UCD90910"
- default n
- help
- If you say yes here you get hardware monitoring support for TI
- UCD90120, UCD90124, UCD90160, UCD9090, UCD90910, Sequencer and System
- Health Controllers.
- This driver can also be built as a module. If so, the module will
- be called ucd9000.
- config SENSORS_UCD9200
- tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
- default n
- help
- If you say yes here you get hardware monitoring support for TI
- UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
- Digital PWM System Controllers.
- This driver can also be built as a module. If so, the module will
- be called ucd9200.
- config SENSORS_ZL6100
- tristate "Intersil ZL6100 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Intersil
- ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
- ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
- Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
- This driver can also be built as a module. If so, the module will
- be called zl6100.
- endif # PMBUS
|