12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091 |
- /*
- * Copyright (C) ST-Ericsson SA 2011
- *
- * License Terms: GNU General Public License v2
- * Author: Mattias Wallin <mattias.wallin@stericsson.com> for ST-Ericsson
- * Author: Sundar Iyer for ST-Ericsson
- * sched_clock implementation is based on:
- * plat-nomadik/timer.c Linus Walleij <linus.walleij@stericsson.com>
- *
- * DBx500-PRCMU Timer
- * The PRCMU has 5 timers which are available in a always-on
- * power domain. We use the Timer 4 for our always-on clock
- * source on DB8500.
- */
- #include <linux/of.h>
- #include <linux/of_address.h>
- #include <linux/clockchips.h>
- #include <linux/sched_clock.h>
- #define RATE_32K 32768
- #define TIMER_MODE_CONTINOUS 0x1
- #define TIMER_DOWNCOUNT_VAL 0xffffffff
- #define PRCMU_TIMER_REF 0
- #define PRCMU_TIMER_DOWNCOUNT 0x4
- #define PRCMU_TIMER_MODE 0x8
- #define SCHED_CLOCK_MIN_WRAP 131072 /* 2^32 / 32768 */
- static void __iomem *clksrc_dbx500_timer_base;
- static u64 notrace clksrc_dbx500_prcmu_read(struct clocksource *cs)
- {
- void __iomem *base = clksrc_dbx500_timer_base;
- u32 count, count2;
- do {
- count = readl_relaxed(base + PRCMU_TIMER_DOWNCOUNT);
- count2 = readl_relaxed(base + PRCMU_TIMER_DOWNCOUNT);
- } while (count2 != count);
- /* Negate because the timer is a decrementing counter */
- return ~count;
- }
- static struct clocksource clocksource_dbx500_prcmu = {
- .name = "dbx500-prcmu-timer",
- .rating = 300,
- .read = clksrc_dbx500_prcmu_read,
- .mask = CLOCKSOURCE_MASK(32),
- .flags = CLOCK_SOURCE_IS_CONTINUOUS,
- };
- #ifdef CONFIG_CLKSRC_DBX500_PRCMU_SCHED_CLOCK
- static u64 notrace dbx500_prcmu_sched_clock_read(void)
- {
- if (unlikely(!clksrc_dbx500_timer_base))
- return 0;
- return clksrc_dbx500_prcmu_read(&clocksource_dbx500_prcmu);
- }
- #endif
- static int __init clksrc_dbx500_prcmu_init(struct device_node *node)
- {
- clksrc_dbx500_timer_base = of_iomap(node, 0);
- /*
- * The A9 sub system expects the timer to be configured as
- * a continous looping timer.
- * The PRCMU should configure it but if it for some reason
- * don't we do it here.
- */
- if (readl(clksrc_dbx500_timer_base + PRCMU_TIMER_MODE) !=
- TIMER_MODE_CONTINOUS) {
- writel(TIMER_MODE_CONTINOUS,
- clksrc_dbx500_timer_base + PRCMU_TIMER_MODE);
- writel(TIMER_DOWNCOUNT_VAL,
- clksrc_dbx500_timer_base + PRCMU_TIMER_REF);
- }
- #ifdef CONFIG_CLKSRC_DBX500_PRCMU_SCHED_CLOCK
- sched_clock_register(dbx500_prcmu_sched_clock_read, 32, RATE_32K);
- #endif
- return clocksource_register_hz(&clocksource_dbx500_prcmu, RATE_32K);
- }
- TIMER_OF_DECLARE(dbx500_prcmu, "stericsson,db8500-prcmu-timer-4",
- clksrc_dbx500_prcmu_init);
|