1234567891011121314151617181920 |
- *ImgTec PowerDown Controller (PDC) Watchdog Timer (WDT)
- Required properties:
- - compatible : Should be "img,pdc-wdt"
- - reg : Should contain WDT registers location and length
- - clocks: Must contain an entry for each entry in clock-names.
- - clock-names: Should contain "wdt" and "sys"; the watchdog counter
- clock and register interface clock respectively.
- - interrupts : Should contain WDT interrupt
- Examples:
- watchdog@18102100 {
- compatible = "img,pdc-wdt";
- reg = <0x18102100 0x100>;
- clocks = <&pdc_wdt_clk>, <&sys_clk>;
- clock-names = "wdt", "sys";
- interrupts = <0 52 IRQ_TYPE_LEVEL_HIGH>;
- };
|