123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125 |
- #
- # PMBus chip drivers configuration
- #
- menuconfig PMBUS
- tristate "PMBus support"
- depends on I2C && EXPERIMENTAL
- default n
- help
- Say yes here if you want to enable PMBus support.
- This driver can also be built as a module. If so, the module will
- be called pmbus_core.
- if PMBUS
- config SENSORS_PMBUS
- tristate "Generic PMBus devices"
- default y
- help
- If you say yes here you get hardware monitoring support for generic
- PMBus devices, including but not limited to ADP4000, BMR453, BMR454,
- MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, UDT020, TPS40400,
- and TPS40422.
- This driver can also be built as a module. If so, the module will
- be called pmbus.
- config SENSORS_ADM1275
- tristate "Analog Devices ADM1275 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Analog
- Devices ADM1075, ADM1275, and ADM1276 Hot-Swap Controller and Digital
- Power Monitors.
- This driver can also be built as a module. If so, the module will
- be called adm1275.
- config SENSORS_LM25066
- tristate "National Semiconductor LM25066 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for National
- Semiconductor LM25066, LM5064, and LM5066.
- This driver can also be built as a module. If so, the module will
- be called lm25066.
- config SENSORS_LTC2978
- tristate "Linear Technologies LTC2978 and LTC3880"
- default n
- help
- If you say yes here you get hardware monitoring support for Linear
- Technology LTC2978 and LTC3880.
- This driver can also be built as a module. If so, the module will
- be called ltc2978.
- config SENSORS_MAX16064
- tristate "Maxim MAX16064"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX16064.
- This driver can also be built as a module. If so, the module will
- be called max16064.
- config SENSORS_MAX34440
- tristate "Maxim MAX34440 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX34440, MAX34441, and MAX34446.
- This driver can also be built as a module. If so, the module will
- be called max34440.
- config SENSORS_MAX8688
- tristate "Maxim MAX8688"
- default n
- help
- If you say yes here you get hardware monitoring support for Maxim
- MAX8688.
- This driver can also be built as a module. If so, the module will
- be called max8688.
- config SENSORS_UCD9000
- tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
- default n
- help
- If you say yes here you get hardware monitoring support for TI
- UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
- Controllers.
- This driver can also be built as a module. If so, the module will
- be called ucd9000.
- config SENSORS_UCD9200
- tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
- default n
- help
- If you say yes here you get hardware monitoring support for TI
- UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
- Digital PWM System Controllers.
- This driver can also be built as a module. If so, the module will
- be called ucd9200.
- config SENSORS_ZL6100
- tristate "Intersil ZL6100 and compatibles"
- default n
- help
- If you say yes here you get hardware monitoring support for Intersil
- ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105,
- ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for
- Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464.
- This driver can also be built as a module. If so, the module will
- be called zl6100.
- endif # PMBUS
|