  1. Kernel driver max34440
  2. ======================
  3. Supported chips:
  4. * Maxim MAX34440
  5. Prefixes: 'max34440'
  6. Addresses scanned: -
  7. Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf
  8. * Maxim MAX34441
  9. PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
  10. Prefixes: 'max34441'
  11. Addresses scanned: -
  12. Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
  13. * Maxim MAX34446
  14. PMBus Power-Supply Data Logger
  15. Prefixes: 'max34446'
  16. Addresses scanned: -
  17. Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf
  18. Author: Guenter Roeck <guenter.roeck@ericsson.com>
  19. Description
  20. -----------
  21. This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel
  22. Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
  23. and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
  24. The driver is a client driver to the core PMBus driver. Please see
  25. Documentation/hwmon/pmbus for details on PMBus client drivers.
  26. Usage Notes
  27. -----------
  28. This driver does not auto-detect devices. You will have to instantiate the
  29. devices explicitly. Please see Documentation/i2c/instantiating-devices for
  30. details.
  31. For MAX34446, the value of the currX_crit attribute determines if current or
  32. voltage measurement is enabled for a given channel. Voltage measurement is
  33. enabled if currX_crit is set to 0; current measurement is enabled if the
  34. attribute is set to a positive value. Power measurement is only enabled if
  35. channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
  36. configured for current measurement.
  37. Platform data support
  38. ---------------------
  39. The driver supports standard PMBus driver platform data.
  40. Sysfs entries
  41. -------------
  42. The following attributes are supported. Limits are read-write; all other
  43. attributes are read-only.
  44. in[1-6]_label "vout[1-6]".
  45. in[1-6]_input Measured voltage. From READ_VOUT register.
  46. in[1-6]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
  47. in[1-6]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
  48. in[1-6]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
  49. in[1-6]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
  50. in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
  51. in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
  52. in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
  53. in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
  54. in[1-6]_lowest Historical minimum voltage.
  55. in[1-6]_highest Historical maximum voltage.
  56. in[1-6]_reset_history Write any value to reset history.
  57. MAX34446 only supports in[1-4].
  58. curr[1-6]_label "iout[1-6]".
  59. curr[1-6]_input Measured current. From READ_IOUT register.
  60. curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
  61. curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
  62. curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
  63. curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
  64. curr[1-4]_average Historical average current (MAX34446 only).
  65. curr[1-6]_highest Historical maximum current.
  66. curr[1-6]_reset_history Write any value to reset history.
  67. in6 and curr6 attributes only exist for MAX34440.
  68. MAX34446 only supports curr[1-4].
  69. power[1,3]_label "pout[1,3]"
  70. power[1,3]_input Measured power.
  71. power[1,3]_average Historical average power.
  72. power[1,3]_highest Historical maximum power.
  73. Power attributes only exist for MAX34446.
  74. temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register.
  75. temp1 is the chip's internal temperature. temp2..temp5
  76. are remote I2C temperature sensors. For MAX34441, temp6
  77. is a remote thermal-diode sensor. For MAX34440, temp6..8
  78. are remote I2C temperature sensors.
  79. temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register.
  80. temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register.
  81. temp[1-8]_max_alarm Temperature high alarm.
  82. temp[1-8]_crit_alarm Temperature critical high alarm.
  83. temp[1-8]_average Historical average temperature (MAX34446 only).
  84. temp[1-8]_highest Historical maximum temperature.
  85. temp[1-8]_reset_history Write any value to reset history.
  86. temp7 and temp8 attributes only exist for MAX34440.
  87. MAX34446 only supports temp[1-3].